They can be used for measurement of flowrate of water:
- In pressurised pipes (both for gauge and vacuum pressures
- In Waste Water Treatment Plants
- In pumping stationss
- In industrial plants
- In chemical factories
- In power stations
Operating conditions:
- temperature of liquid - 30°C up to 140°C, temperature of surrounding O°C up to 55°C
- maximum pressure 1,6 Mpa (2,5Mpa)
- full flow conditions (without air bubbles, foam, scaling and sediments)
- installation to siphons
- minimal conductivity of fluid 5 S/cm
- range of measured speeds 0,10 m/S up to 12 m/S
- range of measured flowrates 1 : 30
Uncertainty in field measurement is lower than 1% of actual flowrate
Technical data:
- cover of probe IP 54
- lining of probe tube
RILZAN 0°C up to 70°C - attestation for food,
HARAL 0 °C aľ 140°C - chemical resistance
- material of electrodes - steel NiCr 17246 (Hasteloy, Platinum, Tantal)
- length of connecting cable between probe and evaluating entity max. 10 m
- evaluating unit in wall unit style, protection IP 53 up to IP 64
- power supply of evaluating unit 220V + 10 %, AC,25VA (included waking up of sensor))
- archiving of data - in evaluating unit by connection to PC and connection to recorder
- manipulation by push-button from evaluation unit
- outlets, separated galvanic means
-analogical 0-20 mA,(4 - 20 mA..) 50
-datal (RS 232, RS 485), pulse, binary
- timer for switching and operating of pumps, dosers, samplers etc. according to different programmes